If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Filename: tfs 455d.doc Version 1.1 11.06.2004 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 0 50 50 C dBm Filter specification TFS 455D 1/5 Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 455,0 MHz without any tolerance or limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data Insertion Loss Nominal Frequency Passband Absolute attenuation 300 350 462,5 467,5 kHz MHz MHz MHz ... ... ... ... 350 445 467,5 2000 MHz MHz MHz MHz OTR TCf * ae fN PB aabs typ. value 1,9 fN dB tolerance / limit 2,8 455,0 2,5 dB MHz MHz 39 35 40 36 - 36 1,7 - dB dB dB dB min. min. min. min. 33 31 30 32 dB dB dB dB Operating Temperature Range Storage Temperature Range Temperature Coefficient of Frequency VSWR within PB(at ambient temperature) Input Power Level *) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz). - 10 C ... + 85 C - 45 C ... + 90 C ppm/K max. max. 2:1 20 dBm Generated: Checked / Approved: Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 455d.doc Version 1.1 11.06.2004 VI TELEFILTER Filter characteristic 0 -10 -20 Filter specification TFS 455D 2/5 0 -2 -4 -6 5 4.5 4 3.5 3 2.5 2 1.5 1 0.5 0 463 magnitude in dB -30 -40 -50 -60 magnitude in dB -8 -10 -12 -14 -16 -70 -80 -18 -20 447 0 200 400 600 800 1000 1200 1400 1600 1800 2000 448.6 450.2 451.8 453.4 455 456.6 458.2 459.8 461.4 frequency in MHz frequency in MHz Construction and pin connection (All dimensions in mm) 455D S24 1 2 3 4 5 6 7 8 Ground Input Ground Ground Ground Output Ground Ground Date code: S T U ... Year + week 2004 2005 2006 50 Test circuit L1 2 6 L2 1, 3, 4, 5, 7, 8 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. VSWR Filename: tfs 455d.doc Version 1.1 11.06.2004 VI TELEFILTER Stability characteristics Filter specification TFS 455D 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direc tion Tape (all dimensions in mm) W : 12,00 0,3 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,1 F : 5,50 0,05 G(min) : 0,75 P2 : 2,00 0,05 P1 : 8,00 0,1 D1(min) : 1,50 Ao : 4,30 0,1 Bo : 4,30 0,1 Ct : 9,5 0,1 P1 t Do Date Code P o P2 G Bo F Ct Ko T yp PIN Marker D1 Ao W2 A C N W1 E G W Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 455d.doc Version 1.1 11.06.2004 VI TELEFILTER Air reflow temperature conditions Filter specification TFS 455D 4/5 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods main-heating periods 150 C - 170 C over 200 C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 455d.doc Version 1.1 11.06.2004 VI TELEFILTER History Version 1.0 1.1 Reason of Changes Filter specification TFS 455D 5/5 Name Roizengaft Date 19.11.2003 - Generation of preliminary specification . - Generation of filter specification - Add and change typical value - Add filter characteristic - Change packing (tape and reel) Noack 11.06.2004 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS455D |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |