Part Number Hot Search : 
AN6876 IRG4BC ESM5000 M41464 M79C9 TF1004A MC33982 477M00
Product Description
Full Text Search
 

To Download HF5802D Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Approved by: Checked by: Issued by:
SPECIFICATION
PRODUCT: SAW FILTER MODEL: HF5802D N1952D SIP5D
HOPE MICROELECTRONICS CO.,LIMITED
Tel:+86-755-82973806 Fax:+86-755-82973550
E-mail: sales@hoperf.com http://www.hoperf.com
Page 1 of 1
1.Construction
1.1 Dimension and materials Type : F5802D
1.2. Circuit construction, measurement circuit
2.Characteristics
Standard atmospheric conditions Unless otherwise specified , the standard rang of atmospheric conditions for making measurements and tests is as follows; Ambient temperature : 15 to 35 Relative humidity : 25% to 85% Air pressure : 86kPa to 106kPa
1
Operating temperature rang Operating temperature rang is the rang of ambient temperatures in which the filter can be operated continuously. -10 ~ +60 Storage temperature rang Storage temperature rang is the rang of ambient temperatures at which the filter can be stored without damage. Conditions are as specified elsewhere in these specifications. -40 ~ +70 Reference temperature 2.1 Maximum Rating DC voltage VDC 12 V AC voltage Vpp 10 V 2.2 Electrical Characteristics Source impedance ZS=50 ZL=2k//3pF Load impedance Freq Min Insertion attenuation 57.08MHz 9.9 Reference level 58.83MHz 4.1 55.25MHz 0.5 Relative attenuation 54.33MHz 17.4 52.83MHz 44.0 60.33MHz 41.0 45.08~52.83MHz 35.0 Sidelobe 60.33~65.08MHz 35.0 Reflected wave signal suppression 1.2 us ... 6.0 us after main pulse 40.0 (test pulse 250 ns , carrier frequency 57.08 MHz) Feedthrough signal suppression 1.2 us ... 6.0 us after main pulse 45.0 (test pulse 250 ns , carrier frequency 57.08 MHz) Temperature coefficient Between any terminals Between any terminals +25
TA=25 typ 11.9 5.6 2.0 19.4 50.0 48.0 40.0 40.0 50.0 max 13.9 7.1 3.5 21.4 dB dB dB dB dB dB dB dB dB
52.0 -72
-
dB ppm/k
2
2.3 Environmental Performance Characteristics Item Test condition Allowable change of absolute Level at center frequency(dB) High temperature test < 1.0 70 1000H Low temperature test < 1.0 -40 1000H Humidity test < 1.0 40 90-95% 1000H Thermal shock < 1.0 -20==25==80 20 cycle 30M 10M 30M Solder temperature test < 1.0 Sold temp.260 for 10 sec. Soldering More then 95% of total Immerse the pins melt solder area of the pins should be covered with solder at 260+5/-0 for 5 sec. 2.4 Mechanical Test Item Test condition Vibration test 600-3300rpm amplitude 1.5mm 3 directions 2 H each Drop test On maple plate from 1 m high 3 times Lead pull test Pull with 1 kg force for 30 seconds Lead bend test 90o bending with 500g weigh 2 times 2.5 Voltage Discharge Test Item Test condition Surge test Between any two electrode
Allowable change of absolute Level at center frequency(dB) <1.0 <1.0 <1.0 <1.0
Allowable change of absolute Level at center frequency(dB)
<1.0
3
2.6 Frequency response
4


▲Up To Search▲   

 
Price & Availability of HF5802D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X