coaxial limiters 2690 series outline 1 v 4.00 f eatures n broadband frequency ranges n environmentally sealed n feedback leveling n small size n reduced vswr description m/a - com?s standard limiter series 2690 is a line of co m- pletely passive solid state receiver protectors. they exhibit octave and multi - octave performance using a unique co n- struction technique involving pin diodes in broadband microstrip circuits. careful diode selection allows a variety of device p erformance, trading off peak and average power handling, spike leakage and recovery time. typical insertion loss and vswr curv es are shown below. electrical specifications : t a = 25 c outline 2 part number frequency range (ghz) insertion loss (db) vswr average power (w) peak power (w) recovery time (ns) leakage power (mw) outline drawing 2690 - 1001 1.0 - 2.0 0.7 1.5:1 1.0 100 100 75 1 2690 - 1003 0.9 1.5:1 3.0 1000 1000 100 2 2690 - 1005 2.0 - 8.0 1.1 1.6:1 1.0 100 100 50 1 2690 - 1007 1.3 1.6:1 3.0 1000 1000 100 2 2690 - 1009 8.0 - 18.0 1.8 2.0:1 1.0 100 100 50 1 2690 - 1011 2.3 2.0:1 3.0 1000 1000 100 2 2690 - 1013 2.0 2.0:1 1.0 100 100 50 1 2690 - 1014 2.2 2.0:1 2.0 500 250 75 1 2690 - 1015 2.3 2.0:1 3.0 1000 1000 100 2 2.0 - 18.0 1. insertion loss and vswr measured at 0 dbm input power. 2. peak input power rated at 1 microsecond pulse width, 1% duty into 1.5:1 s ource vswr and 1.15 load vswr. 3. spike leakage energy: 0.5 ergs max. 4. 1 db compression: +7 dbm min.
coaxial limiters 2690 series specifications subject to change without notice. n north america: tel. (800) 366 - 2266 n asia/pacific: tel.+ 81 - 44 - 844 - 8296 , fax + 81 - 44 - 844 - 8298 n europe: tel. +44 (1344) 869 595, fax+44 (1344) 300 020 visit www.macom.com for additional data sheets and product information. v 4.00 2 environmental test mil - std method cond non - destructive bond pull 883 2023 ? internal visual 883 2017 ? stabilization bake 883 1008 b thermal cycle 883 1010 b constant acceleration 883 2001 a (y1 axis) burn - in 883 1015 125c seal fine gross 883 883 1014 1014 a1 c1 external visual 883 2009 ? absolute maximum ratings 5 5. operation of this device above any one of these parameters may cause permanent damage. parameter absolute maximum operating temperature - 55c to +85c storage temperature - 65c to +125c devices are designed to meet the above screening conditions. typical performance curves vswr insertion loss leakage power at 100 mw -4.0 -3.0 -2.0 -1.0 0.0 2 4 6 10 12 14 16 18 frequency (ghz) insertion loss (db) 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 2 4 6 8 10 12 14 16 18 frequency (ghz) vswr (ratio) 0 5 10 15 20 25 0 10 20 30 40 50 60 power in (dbm) power out (dbm)
|