  specifications features data sheet fkp ... 4 fcx ?c 2 2 2 2 2 min. the fcx ? 2 pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20ma sig- nal. the transmitter utilizes the unique micromachined capaci- tive silicon sensor with state-of-the-art microprocessor tech- nology to provide exceptional performance and functionality. 1. high accuracy 0.1% 0.1% accuracy is a standard feature. fuji? micro-capaci- tance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional ad- justment. 2. minimum environmental influence the ?dvance floating cell?design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 3. fuji/hart bilingual communications protocol and foundation fieldbus and profibus compatibility fcx? 2 series transmitter offers bilingual communica- tions to speak both fuji proprietary protocol and hart . any hart compatible devices can communicate with fcx? 2 . further, by upgrading electronics founda- tion fieldbus and profibus are also available. 4. application flexibility various options that render the fcx c 2 suitable for al- most any process applications include: analog indicator at either the electronics side or ter- minal side full range of hazardous area approvals built-in rfi filter and lightning arrester 5-digit lcd meter with engineering unit 5. burnout current flexibility (under scale: 3.2 to 3.8ma, over scale: 20.8 to 21.6ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 6. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. functional specifications service: liquid, gas, or vapour span, range and overrange limit: overrange limit [mpa] {bar} type fkp ? 01 fkp ? 02 fkp ? 03 fkp ? 04 lower range limit (vacuum limit) is; silicone fill sensor: see fig. 1 fluorinated fill sensor: 66kpa abs (500mmhg abs) at below 80 c conversion factors to different units; 1 mpa=10 3 kpa=10bar=10.19716kgf/cm 2 = 145.0377psi 1kpa=10mbar=101.9716mmh 2 o =4.01463inh 2 o output signal: 4 to 20ma dc with digital signal super- imposed on the 4 to 20ma signal. span limit [kpa] {bar} range limit [kpa] {bar} max. ?00 to +130 {? to +1.3} ?00 to +500 {? to +5} ?00 to +3000 {? to +30} ?00 to +10000 {? to + 100} 8.125 {0.08125} 31.25 {0.3125} 187.5 {1.875} 625 {6.25} 130 {1.3} 500 {5} 3000 {30} 10000 {100} 1 {10} 1.5 {15} 9 {90} 15 {150} pressure transmitter date EDSX5-87A jun. 1, 2006
fkp ... 4 2 power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. load limitations: see figure below note: for communication with hhc (1) (model: fxw), min. of 250 ? required. hazardous locations: (approval pending) 2000 [ ? ] 1500 1000 load resistance 500 250 1533 ? 600 ? operating area 24v 45v 10 16.1 50 [ v ] 10.5v power voltage a tex ex ii 2 gd eex d iic t6 ip66/67 t85 c tamb = -40 c to +65 c eex d iic t5 ip66/67 t100 c tamb = -40 c to +85 c factory mutual class i div.1 groups b, c, d t6 type 4x class ii iii div.1 groups e, f, g t6 type 4x tamb max = +60 c authorities flameproof iecex scheme /saa ex d iic t5 ip66/67 pending tamb = -40 c to +85 c ex d iic t6 ip66/67 pending tamb = -40 c to +65 c csa class i div.1 groups c, d class ii div.1 groups e, f, g class iii div.1 note) ?eal not required?enclosure is allowed. a tex ex ii 1 gd eex ia iic t5 tamb = -40 c to +40 c eex ia iic t4 tamb = -40 c to +80 c entity parameters: ui=28v, ii=93.3ma, pi=0.66w, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.134mh factory mutual class i ii iii div.1 groups a, b, c, d, e, f, g t4 entity type 4x entity parameters: vmax=42.4v, imax=113ma, pi=1w, ci=34.2nf, li=1.134mh authorities intrinsic safety iecex scheme /saa ex ia iic t4 ip66/67 tamb = -40 c to +70 c ex ia iic t5 ip66/67 tamb = -40 c to +50 c entity parameter: ui=28v, ii=93.3ma, pi=0.66w, ci=0.033 f, li=1.034mh csa class i div.1 groups a, b, c, d class ii div.1 groups e, f, g class iii div.1 t emp code t4 tamb max = +40 c t emp code t3c tamb max = +85 c entity parameters: vmax=28v, imax=93ma, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.4mh model code 9th digit 13th digit t amb a,b,d y, g , n-40 c to +85 c l,p,1,2 y, g , n-20 c to +80 c q,s,4,5 y, g , n-20 c to +60 c e,f,h y, g , n-40 c to +60 c - a -10 c to +60 c
3 ?utput underscale? adjustable within the range 3.2ma to 3.8ma from hhc 3.8 3.2 4 20 20.8 21.6 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout (note) (1) hhc: hand held communicator loop-check output: transmitter can be configured to provide constant signal 3.8ma through 21.6ma by hhc. temperature limit: ambient: 40 to +85 c (?0 to +80 c for lcd indicator) ( 40 to +60 c for arrester option) (?0 to +60 c for fluorinated oil fill transmitter) for explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified by each standard. process: 40 to +100 c for silicone fill sensor ?0 to +80 c for fluorinated oil fill sen- sor storage: ?0 to +90 c humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following informa- tion can be remotely displayed or recon- figured. note: hhc? version must be more than 6.0 (or fxw 1 3), for fcx- c 2 . zero/span adjustment : zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw (span adjustment not available with 9th digit code ?, p, q, s?. damping: adjustable from hhc or local adjustment unit with lcd display. the time constant is adjustable between 0.12 to 32 seconds. zero elevation/suppression: zero can be elevated or suppressed within the specified range limit of each sensor model. normal/reverse action: selectable from hhc (1) . indication: analog indicator or 5-digit lcd meter, as specified. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?utput hold? ?utput overscale or ?utput underscale?modes. ?utput hold? output signal is hold as the value just be- fore failure happens. ?utput overscale? adjustable within the range 20.8ma to 21.6ma from hhc (1) tag no. model no. serial no. engineering unit range limit measuring range damping output mode burnout direction calibration output adjust data self diagnoses printer external switch lock transmitter display linearize rerange items display set vv vv v vv v vv vv v vv vv ? v v vv vv vv vv (note) (1) hhc: hand held communicator a tex ex ii 3 gd eex nl iic t5 tamb = -40 c to +40 c eex nl iic t4 tamb = -40 c to +80 c specific parameters: model without arrester: ui=42.4v, ii=113ma, pi=1w, ci=27nf, li=1.134mh model with arrester: ui=32v, ii=113ma, pi=1w, ci=34.2nf, li=1.134mh eex nal iic t5 tamb = -40 c to +40 c eex nal iic t4 tamb = -40 c to +80 c specific parameters: model without arrester: umax=42.4v, imax=113ma, pmax=1w, model with arrester: umax=32v, imax=113ma, pmax=1w factory mutual class i ii iii div.2 groups a, b, c, d, f, g t4 entity type 4x authorities t ype n nonincendive iecex scheme /saa - csa class i div.2 groups a, b, c, d class ii div.2 groups e, f, g class iii div.2 t emp code t4 tamb max = +40 c t emp code t3c tamb max = +85 c entity parameters: vmax=28v, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.4mh model code 9th digit 13th digit t amb a,b,d y, g , n-40 c to +85 c l,p,1,2 y, g , n-20 c to +80 c q,s,4,5 y, g , n-20 c to +60 c e,f,h y, g , n-40 c to +60 c - a -10 c to +60 c
fkp ... 4 4 physical specifications electrical connections: g1/2, 1/2-14 npt, pg13.5, or m20  1.5 conduit, as specified. process connections: 1/2-14npt, rc1/2, rc1/4 or 1/4-18npt, as specified. process-wetted parts material: performance specifications accuracy rating: (including linearity, hysteresis, and re- peatability) for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url (model fkp only): (0.05 + 0.05 ) % of span stability: 0.1% of upper range limit (url) for 6 months temperature effect: effects per 55 c change between the lim- its of ?40 c and +85 c zero shift : (0.1 )%/28 c total effect: (0.075 + 0.1 )%/28 c overrange effect: zero shift, 0.3% of url for any overrange to maximum limit supply voltage effect: less than 0.05% fo calibrated span per 10v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and field strength 30 v/m when electronics covers on. (classification: 2-abc: 0.2% span per sama pmc 33.1) update period: 120 msec step response: time constant: 0.2s dead time: about 0.2s (without electrical damping) mounting position effect: zero shift, less than 0.1kpa {1mbar} for a 10 tilt in any plane. no effect on span. this error can be cor- rected by adjusting zero. (double the effect for fluorinated fill sen- sors) dielectric strength: 500v ac, 50/60hz 1 min., between circuit and earth insulation resistance: more than 100m ? at 500v dc turn-on time: 4 sec. internal resistance for external field indicator: 12 ? or less. v 316 stainless steel material code (7th digit in code symbols) process cover diaphragm wetted sensor body 316 stainless steel 316l stainless steel non-wetted parts material: electronics housing: low copper die-cast aluminum alloy (standard), finished with epoxy/polyurethane double coat- ing. fill fluid: silicone oil (standard) or fluori- nated oil (daifloil) mounting bracket: 304 stainless steel environmental protection: iec ip67 and nema 6/6p mounting: on 60.5mm (jis 50a or 2b) pipe using mounting bracket, direct wall mounting, or direct process mounting. mass{weight}: transmitter approximately 1.9kg without options. add; 0.5kg for mounting bracket 0.8kg for indicator option 0.1 x url span url span url span
5 optional features indicator: a plug-in turnable analog indicator (1.5% accuracy) can be housed in the electronics compartment or in the terminal box of the housing. an optional 5digits lcd meter with engi- neering unit is also available. local adjustment unit with lcd display: an optional 5-digit lcd meter with zero/ span adjustment function, loop-check function and damping adjustment func- tion, is available. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 x 50 s) oxygen service: special cleaning procedures are followed throughout the process to maintain all pro- cess wetted parts oil-free. the fill fluid is fluorinated oil. degreasing: process-wetted parts are cleaned, but the fill fluid is standard silicone oil. not for use for oxygen or chlorine measurement. nace specification: metallic materials for all pressure bound- ary parts comply with nace mr-01-75. optional tag plate: an extra stainless steel tag with customer tag data is wired to the transmitter. hand-held communicator: (model fxw, refer to data sheet no. eds8-47) z/s board: parts no.=zzpfcx4-a070 when z/s board is mounted on the fcx c 2 amplifier unit, external adjustment screw will be available for zero and span adjustment. fig. 1 relation between process temperature and operating pressure ?0 60 100 none-operating area 2.7 (20) 4 (30) 20 operating pressure process temperature[ c ] (150) 101 (760) [kpa abs] (mmhg abs) silicone oil (code:y,g,n) operating area accessories the product conforms to the requirements of the electromagnetic compatibility directive 94/9/ec as detailed within the technical construction file number tn513035. the applicable standards used to demonstrate compliance are : frequency range mhz limits reference standard 30 to 230 40db ( v/m) quasi peak, measured at 10m distance 230 to 1000 47db ( v/m) quasi peak, measured at 10m distance cispr16-1 and cispr16-2 phenomenon test value basic standard performance criteria b electrostatic discharge conducted rf 0.15 to 80mhz 3v 80%am (1khz) electromagnetic field 4kv (contact) 8kv (air) 80 to 1000mhz 10v/m 80%am (1khz) iec61000-4-2 burst a iec61000-4-3 rated power frequency magnetic field 30a/m 50hz a iec61000-4-8 2kv 5khz b iec61000-4-4 surge 1.2 s/50 s 1kv (line to line) 2kv (line to ground) b iec61000-4-5 a iec61000-4-6 emi (emission) en61326 : 1997 class a (standard for industrial location) emi (immunity) en61326: 1997 annex a (standard for industrial location) note) definition of performance criteria a: during testing, normal performance within the specification limits. b: during testing, temporary degradation, or loss of function or performance which is self-recovering.
fkp ... 4 6 code symbols a b d e f h l p q s 1 2 4 5 a d e x r h j k p t y g a n y b a c y a b c process conn. conduit conn. g1/2 1/2-14npt 1/2-14npt pg 13.5 m20 x 1.5 fkp kpa {bar} 8.125 ? 130 {0.08125 ? 1.3} 31.25 ? 500 {0.3125 ? 5} 187.5 ? 3000 {1.875 ? 30} 625 ?0000 {6.25 ?00} process cover diaphragm wetted cell body 316 stainless steel 316l stainless steel 316 stainless steel indicator arrester none none analog, 0 to 100% linear scale none analog, custom scale none none yes analog, 0 to 100% linear scale yes analog, custom scale yes digital, 0 to 100% linear scale none digital, custom scale none digital, 0 to 100% linear scale yes digital, custom scale yes digital, 0 to 100% (local adjustment unit with lcd displey) none digital, custom scale (local adjustment unit with lcd displey) none digital, 0 to 100% (local adjustment unit with lcd displey) yes digital, custom scale (local adjustment unit with lcd displey) yes none (for ordinary locations) fm, flameproof (or explosionproof) (available for 4th code "t") csa flameproof (or explosionproof) (available for 4th digit code "t") atex, flameproof iecex scheme/saa, flameproof (approval pending) fm, intrinsic safety and nonincendive csa intrinsic safety and nonincendive atex, intrinsic safety atex, type n iecex scheme/saa, intrinsic safety none yes (stainless steel) stainless tag none yes treatment filled liquid none (standard) silicon oil degreasing silicon oil oxygen service fluorinated oil nace specification silicon oil none (1/2 -14npt) rc1/4 rc1/2 1/4-18npt s t v w 1 2 3 4 v 4567 123 f0 0 4 kp 89 10 11 12 13 14 15 z/s board attached. note digit 4 6 7 9 10 11 12 13 14 description digit no. of code
7 outline diagram (unit:mm) connection diagrams note) cable gland is supplied in case of flameproof packing type. 11 cable is suitable. see table 1 with field ind. (option) up down ? conduit conn. 2 holes 9 dia. zero/span adj. screw in case of 4th digit code ? s,v,w ? see table 1 fastener (in case of 10th digit code ? x ? ) cable gland (option) see note ? conduit conn. earth terminal (both side) see table 1 earth terminal rc1/2 4th digit code m4 31 m4 m4 m4 25 table 1 detail ? (press. conn.) detail ? (conduit conn.) detail ? 14 44 conn. l conduit conn. d g1/2 pg13.5 1/2-14npt 4.5 16 16 17 npt1/4 rc1/4 22 27 table 2 17  1/2 13 e d 15 16 1/2-14npt 18 f 100 10 50 88 196 51 214 71 80 (27) e f 8 8 5 5 m20x1.5 s t w v g h j   ck  ck    16 k 8 adapter 6 k l detail ? 170 y hexagon socket head cap screw m4 h j 35 g 27 85 70 ? press. conn. ? adapter (option) see teble2 u-bolt m8 mtg. pipe jis 50a (2b) 108 80
fkp ... 4 information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDSX5-87A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X